With the Fixturlaser NXA Flatness package you measure flatness in a circle or flatness in a rectangle. Applications include checking flanges and foundations, or leveling machines.
For measuring flatness, you can choose between the Fixturlaser T220 and the Fixturlaser T21 laser transmitter.
User-friendly measuring equipment
The graphical user interface is displayed on a 6.5″ transreflective display with accompanying icons and symbols, i.e. without text.
The adaptive user interface guides you through the measurement process.



This system can be used for, for example, measuring base frames for machines. The combination of a flatness measurement (to check the surface for flatness) and an axis alignment (to align the machine) ensures a longer service life of the bearings.

Fixturlaser NXA Geometry |
|
Fixturlaser RM/RS Sensor unit | |
Weight | 116 g (4.09 oz) |
Dimensions (with cable attached) | 57 mm x 50 mm x 40 mm (2.2 in x 2.0 in x 1.6 in) |
Detector size | 20 mm x 20 mm (0.8 in x 0,8 in) |
Measurement accuracy | 1% ± 3 µm |
BT2 Wireless unit | |
Weight | 190 g (6.7 oz) with batteries |
Dimensions | 82 mm x 50 mm x 40 mm (3.2 in x 2.0 in x 1.6 in) |
Wireless communication | Class II Bluetooth transmitter |
Communication range | 10 m (33 ft) |
Power supply | 3 AA (LR6) batteries |
Operating time | 10 hours continuously |
T110 Transmitter | |
Operating temperature | 0 to 50°C (32 to 122°F) |
Storage temperature | -20 to 70°C (-4 to 158°F) |
Weight | 1100 g (2.43 lbs) |
Laser | 650 nm class II diode laser |
Dimensions | 60 mm x 60 mm x 140 mm (2.4 in x 2.4 in x 5.5 in) |
Measurement distance | Up to 50 m (164 ft) |
Power supply | 2 batteries type LR6 (AA) |
Operating time | 15 hours |
T111 Transmitter | |
Operating temperature | 0 to 50°C (32 to 122°F) |
Storage temperature | -20 to 70°C (-4 to 158°F) |
Weight | 1030 g (2.27 lbs) |
Dimensions | 60 mm x 60 mm x 140 mm (2.4 in x 2.4 in x 5.5 in) |
Laser | 650 nm class II diode laser |
Measurement distance | Up to 50 m (164 ft) |
Power supply | AC-adapter 110/230 Volts |
T21 Transmitter | |
Operating temperature | 0 to 50°C (32 to 122°F) |
Storage temperature | -20 to 70°C (-4 to 158°F) |
Weight | 1150 g (2.54 oz) |
Dimensions | 100 mm x 103 mm x 109 mm (3.9 in x 4.0 in x 4.2 in) |
Laser | 650 nm class II diode laser |
Measurement distance | Up to 20 m (66 ft) |
Laser sweep flatness | ±0.02 mm/m |
Angular prism accuracy | ±0.02 mm/m |
Power supply | 2 batteries type LR6 (AA) |
Operating time | 15 hours |
T220 Transmitter | |
Operating temperature | 0 to 50°C (32 to 122°F) |
Storage temperature | -20 to 70°C (-4 to 158°F) |
Weight | 3500 g (7.72 lbs) |
Dimensions | 175 mm x 175 mm x 115 mm (6.9 in x 6.9 in x 4.5 in) |
Laser | 650 nm class II diode laser |
Measurement distance | Up to 50 m (164 ft) |
Laser sweep flatness | ±0.02 mm/m |
Angular prism accuracy | ±0.02 mm/m |
Power supply | 4 batteries type LR6 (AA) |
Operating time | 15 hours |